Medical Catheter Flexible Printed Circuit (Catheter FPC) is a miniature flexible interconnect embedded inside active interventional catheters for minimally invasive procedures. Fabricated mainly on polyimide (PI) substrate with etched copper circuits, it replaces bundles of discrete fine wires. It transmits bioelectric sensing signals, excitation signals, RF energy and high-speed imaging signals, and integrates electrodes, pressure/temperature sensors, ultrasound transducers and other components. It serves as the core interconnection medium running from the proximal handle all the way to the catheter distal tip.

Main Applications

Key Advantages over Traditional Fine Wires

  1. Eliminates wire tangling and simplifies threading into tiny lumens, greatly cutting assembly time

  2. Minimizes solder joints at the distal tip, lowering failure risks and boosting reliability

  3. Supports ultra-fine line & space, ultra-narrow and long form factor to fit small French-size catheters

  4. Stable electrical performance with controlled impedance and shielding options to reduce crosstalk, ideal for weak bio-signals and high-frequency signals

  5. Convenient continuity and isolation testing in one pass instead of testing wires one by one

  6. Superior dynamic flexibility to withstand repeated bending and torsion during catheter navigation

Typical Materials & Stack-up (Medical Grade)

  1. Substrate: Adhesiveless polyimide (PI) is preferred for EO and gamma sterilization resistance; PET is rarely used

  2. Conductor: Rolled Annealed (RA) copper for cyclic bending fatigue resistance; Electrodeposited (ED) copper for static bending scenarios

  3. Coverlay: PI coverlay with defined openings for electrodes and bond pads; soft gold plating on exposed pads for biocompatible electrodes and wire bonding

  4. Optional layers: EMI shielding; stiffener on the proximal section for ZIF connector soldering

Critical Technical & Quality Requirements

  1. Miniaturization: ultra-thin, ultra-narrow HDI fine circuits

  2. Flex and torsion reliability under clinical manipulation

  3. Biocompatibility: ISO 10993 compliance (cytotoxicity, sensitization, hemolysis etc.)

  4. Sterilization compatibility: stable after EO or gamma irradiation without delamination or leaching

  5. High dielectric strength, low ionic contamination and particle control per AAMI TIR42

  6. Full batch traceability under ISO 13485 quality management system

  7. Signal integrity and differential impedance control for high-frequency imaging versions

Zones of Structure