Medical Catheter Flexible Printed Circuit (Catheter FPC) is a miniature flexible interconnect embedded inside active interventional catheters for minimally invasive procedures. Fabricated mainly on polyimide (PI) substrate with etched copper circuits, it replaces bundles of discrete fine wires. It transmits bioelectric sensing signals, excitation signals, RF energy and high-speed imaging signals, and integrates electrodes, pressure/temperature sensors, ultrasound transducers and other components. It serves as the core interconnection medium running from the proximal handle all the way to the catheter distal tip.
Main Applications
Electrophysiology (EP) catheters for cardiac mapping and RF / PFA ablation
Intravascular Ultrasound (IVUS) and Intracardiac Echocardiography (ICE) catheters
Optical Coherence Tomography (OCT) imaging catheters
Intravascular pressure and temperature monitoring catheters
Multimodal therapeutic catheters for neuro-intervention and tumor ablation
Key Advantages over Traditional Fine Wires
Eliminates wire tangling and simplifies threading into tiny lumens, greatly cutting assembly time
Minimizes solder joints at the distal tip, lowering failure risks and boosting reliability
Supports ultra-fine line & space, ultra-narrow and long form factor to fit small French-size catheters
Stable electrical performance with controlled impedance and shielding options to reduce crosstalk, ideal for weak bio-signals and high-frequency signals
Convenient continuity and isolation testing in one pass instead of testing wires one by one
Superior dynamic flexibility to withstand repeated bending and torsion during catheter navigation
Typical Materials & Stack-up (Medical Grade)
Substrate: Adhesiveless polyimide (PI) is preferred for EO and gamma sterilization resistance; PET is rarely used
Conductor: Rolled Annealed (RA) copper for cyclic bending fatigue resistance; Electrodeposited (ED) copper for static bending scenarios
Coverlay: PI coverlay with defined openings for electrodes and bond pads; soft gold plating on exposed pads for biocompatible electrodes and wire bonding
Optional layers: EMI shielding; stiffener on the proximal section for ZIF connector soldering
Critical Technical & Quality Requirements
Miniaturization: ultra-thin, ultra-narrow HDI fine circuits
Flex and torsion reliability under clinical manipulation
Biocompatibility: ISO 10993 compliance (cytotoxicity, sensitization, hemolysis etc.)
Sterilization compatibility: stable after EO or gamma irradiation without delamination or leaching
High dielectric strength, low ionic contamination and particle control per AAMI TIR42
Full batch traceability under ISO 13485 quality management system
Signal integrity and differential impedance control for high-frequency imaging versions
Zones of Structure
Distal end: Exposed electrode pads for transducers and ablation contacts, the thinnest and most flexible section
Flexible run: Main long routing section passing through the catheter lumen
Proximal end: Widened area with stiffener, bonded to ZIF connectors or rigid PCB